Skip to content
Kozhikode, Kerala · Serving hospitals & businesses across India+91 96563 43720info@fluxionsolution.com
FluxLink · Laboratory Analyzer Integration Bridge

One bridge. Every analyzer.

FluxLink connects directly to your diagnostic analyzers, reads every result the moment it's produced, matches it to the correct sample by barcode, and delivers it straight to your LIS and cloud — automatically, with no manual entry and no transcription errors.

  • HL7 v2.3.1
  • ASTM E1394 / LIS01-A
  • RS232 Serial
  • TCP/IP
3D illustration of a lab analyzer connected through the FluxLink bridge to the cloud and a patient report
Result received · CBCHematology analyzer · 0.4 s
Barcode matchedSMP-20931 · Anitha N.
Synced to LIS & cloudHistograms attached
How it works

From instrument to report, without a keystroke

FluxLink runs quietly alongside your instruments and keeps every result moving — in both directions.

  1. AnalyzersHematology, biochemistry, immunoassay
  2. FluxLinkHL7 · ASTM parsing, barcode matching, queue & audit log
  3. Your LISResults land on the right sample
  4. CloudQueued & synced, retries on failure
  5. Patient reportValues plus histograms & scattergrams
Test orders down to the analyzerBi-directional: the analyzer knows what to run for each barcode.
Results back up to the LISEvery value, flag and graph — the moment it's produced.
Capabilities

Built to speak every instrument's language

HL7 & ASTM / LIS01-A

Speaks HL7 v2.3.1 and ASTM E1394 / LIS01-A, so most analyzers connect with no firmware changes.

RS232 & TCP/IP

Works over both serial cables and network connections, for older and newer instruments alike.

Bi-directional

Sends test orders down to the analyzer and brings results back up to your LIS.

Many instruments, one pipeline

Runs multiple analyzers side by side — hematology, biochemistry and immunoassay share one reliable data pipeline.

Histograms & scattergrams

RBC, PLT and WBC histograms and differential scattergrams are captured and attached to the patient report.

Barcode matching

Every result is tied to its own barcode, so the right value always reaches the right patient.

Resilient cloud sync

Results and graphs are queued and synced. A dropped network never loses data — it simply retries.

Auto-reconnect & audit log

Reconnects on its own, and a complete audit log records every byte received.

Beyond numbers

The full clinical picture on every report

FluxLink pulls RBC, PLT and WBC histograms and differential scattergrams straight from the analyzer and attaches them to the patient report — next to every value, matched by barcode.

  • RBC, PLT & WBC histograms
  • Differential scattergrams
  • Flags and values, exactly as the analyzer produced them
Complete Blood CountAnitha Nair · 34 F · SMP-20931 · Hematology analyzer
TestResultUnitReference
Haemoglobin12.8g/dL12.0 – 15.5
WBC count11.6 H10³/µL4.0 – 11.0
Platelet count2.45lakh/µL1.5 – 4.1
Supported standards

Connects to most analyzers with no firmware changes

FluxLink supports the protocols and connections laboratory instruments already use, so setup is about configuration — not custom development.

HL7 v2.3.1Health Level Seven messaging
ASTM E1394LIS01-A low-level protocol
RS232 SerialDirect cable to the instrument
TCP/IPNetwork-connected analyzers
Multi-instrument

Your whole lab on one data pipeline

HematologyCBC with histograms & scattergrams
● Online
BiochemistryLFT, RFT, lipid and more
● Online
ImmunoassayHormones and markers
● Reconnecting
Built-in resilience

A dropped network never loses a result

Results and graphs are queued and synced to the cloud. If the connection drops, FluxLink simply retries. A complete audit log records every byte received.

  • Queued delivery with automatic retries
  • Reconnects to instruments on its own
  • Complete byte-level audit log
FAQ

FluxLink — common questions

Which communication standards does FluxLink support?

FluxLink supports HL7 v2.3.1 and ASTM E1394 / LIS01-A, over both RS232 serial and TCP/IP connections.

Do our analyzers need firmware changes?

Usually not. Because FluxLink speaks the HL7 and ASTM / LIS01-A protocols analyzers already use, most analyzers connect with no firmware changes. Tell us your analyzer models and we will confirm compatibility.

Can FluxLink send test orders to the analyzer?

Yes. FluxLink works in both directions: it sends test orders down to the analyzer and brings results back up to your LIS.

Can one FluxLink connect several analyzers?

Yes. FluxLink runs multiple instruments side by side, so your hematology, biochemistry and immunoassay analyzers share one reliable data pipeline.

What happens if the internet connection drops?

Nothing is lost. Results and graphs are queued and synced to the cloud with built-in resilience: if the network drops, FluxLink simply retries. A complete audit log records every byte received.

Free demo · Personalised for you

One bridge. Every analyzer.

From instrument to report, automatically. Tell us your analyzer models and we'll confirm compatibility.

  • Online or on-site demo
  • No obligation
  • Local team in India